Mac 1200 Ecg Machine User Manual
2021年2月25日Download here: http://gg.gg/ofpr1
*Mac 1200 Ecg Machine User Manual Pdf
*Mac 1200 Ecg Machine User Manual DownloadMac 1200 Ecg Machine User Manual PdfTips for buying ECG
*A multichannel ECG should record the standard 12 leads. It should have at least 3 channels of simultaneous ECG data, and be capable of simultaneous acquisition of all 12 leads. It should measure all basic axes and durations including: RR, PQ, QT, ATC, P, QRS, T, and HR.
*Battery status markers should be available on the electrocardiograph, as well as indicators for loose electrode contact, systems status, and artifacts.
*The device should be able to store ECG waveforms for later retrieval, printing, and transmission.
*The ECG should enable the user to enter patient data, which should include the patient’s name or ID number, age, sex, weight, and height. The data will also contain the recording date and time, sensitivity setting, chart speed, and leads being recorded.
*The ECG device should have an RS232 port or other appropriate digital interface to allow its communications with other devices such as electrocardiographs, computers, or a data management system.
*The ECG may come with a complete interpretation software package and should store at least 20 ECGs. It can also include an expandable storage capability.
*The unit should be able to print at least 3 leads of the ECG waveform continuously with manual switching between leads. It should provide sensitivity settings of at least 2.5, 5, 10, and 20 mm/mV and recorders with a typical chart speed of 5, 10, 25, and 50 mm/sec.
*ECG devices designed for adult defibrillation should have energy settings of 50-360 J.
*ECG devices capable of internal or pediatric defibrillation or synchronized cardio version should have energy settings of 5-50 J.
*ECG devices for neonatal applications should have additional low-energy settings of 1-20 J.
*Units should be able to charge to maximum energy in less than 15 seconds over the full range of battery-charge indicator levels.
*The unit should automatically disarm within two minutes if not intentionally discharged.
*Interpretative electrocardiograph units should have the option of running on battery power. Line-powered ECG units will not disarm when the line cord is unplugged or when line power is otherwise interrupted.
*The monitor should display a clear and distinct marker to indicate the synchronization point on the ECG waveform.
*The defibrillator’s ECG input amplifiers should be protected against damage from discharge energy.
*The display should recover a readable ECG trace within five seconds of an input overload from a maximum-energy defibrillator pulse.
*The interpretative electrocardiograph unit should include a recorder, and the recorded strip should include periodic annotations. Mac 1200 Ecg Machine User Manual Download
The MAC 1200 is an ECG acquisition and recording system designed and manufactured by Marquette Medical Systems. − It is intended to be used for resting ECG recording and realtime ECG recording with or without arrhythmia detection. − It is not intended for use as a vital signs physiological monitor. − The arrhythmia detection portion of the MAC 1200 is provided to the customer for the convenience of automatic documentation. The MAC 1600 ECG Analysis System is a 12-lead, 12-channel system with a 6.5 inch (165 mm) diagonal display, active patient cable, and battery operation. There are also options for communication capabilities. Powerline 1200 User Manual Models PL1200 PLP1200 January 2016 202-11566-01 350 E. Plumeria Drive San Jose, CA 95134 USA. Online Payment via ACLEDA E-Commerce’s User Manual Help us improve our services quality. Do you have 10 minutes of your time to help us improve our services quality?
Download here: http://gg.gg/ofpr1
https://diarynote-jp.indered.space
*Mac 1200 Ecg Machine User Manual Pdf
*Mac 1200 Ecg Machine User Manual DownloadMac 1200 Ecg Machine User Manual PdfTips for buying ECG
*A multichannel ECG should record the standard 12 leads. It should have at least 3 channels of simultaneous ECG data, and be capable of simultaneous acquisition of all 12 leads. It should measure all basic axes and durations including: RR, PQ, QT, ATC, P, QRS, T, and HR.
*Battery status markers should be available on the electrocardiograph, as well as indicators for loose electrode contact, systems status, and artifacts.
*The device should be able to store ECG waveforms for later retrieval, printing, and transmission.
*The ECG should enable the user to enter patient data, which should include the patient’s name or ID number, age, sex, weight, and height. The data will also contain the recording date and time, sensitivity setting, chart speed, and leads being recorded.
*The ECG device should have an RS232 port or other appropriate digital interface to allow its communications with other devices such as electrocardiographs, computers, or a data management system.
*The ECG may come with a complete interpretation software package and should store at least 20 ECGs. It can also include an expandable storage capability.
*The unit should be able to print at least 3 leads of the ECG waveform continuously with manual switching between leads. It should provide sensitivity settings of at least 2.5, 5, 10, and 20 mm/mV and recorders with a typical chart speed of 5, 10, 25, and 50 mm/sec.
*ECG devices designed for adult defibrillation should have energy settings of 50-360 J.
*ECG devices capable of internal or pediatric defibrillation or synchronized cardio version should have energy settings of 5-50 J.
*ECG devices for neonatal applications should have additional low-energy settings of 1-20 J.
*Units should be able to charge to maximum energy in less than 15 seconds over the full range of battery-charge indicator levels.
*The unit should automatically disarm within two minutes if not intentionally discharged.
*Interpretative electrocardiograph units should have the option of running on battery power. Line-powered ECG units will not disarm when the line cord is unplugged or when line power is otherwise interrupted.
*The monitor should display a clear and distinct marker to indicate the synchronization point on the ECG waveform.
*The defibrillator’s ECG input amplifiers should be protected against damage from discharge energy.
*The display should recover a readable ECG trace within five seconds of an input overload from a maximum-energy defibrillator pulse.
*The interpretative electrocardiograph unit should include a recorder, and the recorded strip should include periodic annotations. Mac 1200 Ecg Machine User Manual Download
The MAC 1200 is an ECG acquisition and recording system designed and manufactured by Marquette Medical Systems. − It is intended to be used for resting ECG recording and realtime ECG recording with or without arrhythmia detection. − It is not intended for use as a vital signs physiological monitor. − The arrhythmia detection portion of the MAC 1200 is provided to the customer for the convenience of automatic documentation. The MAC 1600 ECG Analysis System is a 12-lead, 12-channel system with a 6.5 inch (165 mm) diagonal display, active patient cable, and battery operation. There are also options for communication capabilities. Powerline 1200 User Manual Models PL1200 PLP1200 January 2016 202-11566-01 350 E. Plumeria Drive San Jose, CA 95134 USA. Online Payment via ACLEDA E-Commerce’s User Manual Help us improve our services quality. Do you have 10 minutes of your time to help us improve our services quality?